The Calibration Control Kit Handbook

A complete, practical system for measuring equipment in an aerospace shop: know every instrument and what it puts at risk, keep it in calibration, prove it is fit for the job, and handle an out-of-tolerance result the day it happens.

Want it on paper or to edit? The full handbook, with the forms to fill in, is free in Word and PDF: get it free.

The problem it solves

Calibration looks like the easiest part of a quality system: a list, a sticker, a certificate. It is also one of the most reliable sources of audit findings, because the list answers only one question (is it in date?) and the auditor asks three more: what did this instrument measure, what did you do when it failed, and how do you know it is good enough for that tolerance? This handbook is the operating manual for the Calibration Control Kit. It sets out one workflow from receiving an instrument to retiring it, who does what, which tool to use at each step, how to handle an out-of-tolerance result, when a gauge study is needed, the weekly and monthly rhythm, and how to set it all up in thirty days without buying new software.

Who it is for

Quality managers and calibration coordinators who own the measuring equipment system; quality engineers who run gauge studies and impact assessments; the general manager who sponsors it.

When to use it

When calibration findings keep coming back; when an out-of-tolerance result has no product assessment; when a customer asks for gauge studies behind key characteristics; when you take over a quality system; or a quarter before a surveillance or recertification audit.

How to use this handbook

  1. Read chapters 1 to 3: why calibration systems fail audits, the kit, and the workflow it runs.
  2. Agree the roles in chapter 4 with your general manager before you change anything.
  3. Build or rebuild the equipment register (chapter 5) using the Calibration and Measurement Risk Register (E01).
  4. Read chapter 9 before you need it: the first out-of-tolerance result is not the time to learn the method.
  5. Follow the thirty-day setup in chapter 16, and run the weekly and monthly rhythm in chapter 14 from the first week.
  6. Use the worked example in chapter 17 to see every tool used on the same instruments.
  7. Give your general manager the one-page summary in chapter 18, and pin the quick reference (chapter 19) where the calibration work is done.

The chapters

  1. 1Why calibration systems fail auditsCalibration is the clause most shops believe they have covered. There is a list, there are stickers, and the…
  2. 2The kit and how the tools connectFour tools do the work. The register is the backbone; the other three hang off its lines.
  3. 3The calibration control workflowEvery instrument moves through the same loop for as long as it is in use. The shaded boxes are gates: Yes continues…
  4. 4Who does whatA measuring equipment system needs an owner for the system and a clear owner for every instrument.
  5. 5Building the equipment register (E01)The register is one line per instrument used to accept product or control a process.
  6. 6Calibration sources and certificatesMost small shops send most of their calibration out. That is sound practice, and it makes the laboratory an external…
  7. 7Setting and adjusting intervalsAn interval is a bet on how long an instrument stays within its limits in your conditions of use.
  8. 8Between calibrations: checks, handling and conditionsCalibration shows the instrument was good on one day. Interim checks show it stayed good, and they shrink the window…
  9. 9When a calibration fails: the impact assessment (E02)An out-of-tolerance result means every measurement the instrument made since it was last known good is in question…
  10. 10Proving fitness: measurement system analysis (E03, E04)Calibration compares an instrument with a standard. Measurement system analysis asks a different question: is this…
  11. 11Measurement uncertainty and decisions near the limitEvery measurement has some doubt in it: the instrument's own uncertainty, the reference standard's, temperature, the…
  12. 12Software, CMM programs and test equipmentWhen software decides acceptance, the software is part of the measurement system.
  13. 13Records that hold upAn auditor tests a calibration system by following a chain: from a part's inspection record to the instrument, from…
  14. 14The weekly and monthly rhythmThe weekly review has a fixed agenda: anything overdue or quarantined, each with one decision; instruments due in the…
  15. 15Measures that matterMeasure: Share of instruments in use that are in date; Out-of-tolerance results per quarter; Days from finding to a…
  16. 16Setting it up in thirty daysDo: Agree roles and the out-of-tolerance path with the general manager. Walk the floor and collect every instrument…
  17. 17Worked example: the same instruments through the whole kitMeridian Aerostructures machines aluminum housings and brackets on two shifts and inspects them in a small lab.
  18. 18For your general manager: one pageFill this in and hand it over. It says what changes, what you need, and what they will see.
  19. 19Quick referenceWhen: A new instrument arrives; Someone drops or doubts a gauge; A certificate comes back; As found is out of…
  20. 20Situations we meet oftenSituation: The lab adjusted the instrument and reported only as-left data; An employee's own micrometer was used on…
  21. 21The kit at a glanceTool: Calibration and Measurement Risk Register; Out-of-Tolerance Impact Assessment; MSA Planning Worksheet; Gage R&R…
  22. 22Where the kit touches AS9100DClause numbers only; read the requirements in your own copy of the standard. The kit is a way of meeting them in…

Aegis Insights: how we approach this work

Aegis Insights are our own guidance: how we approach this work and why, from years inside aerospace quality systems. They are not requirements of any standard or customer.

Definitions

TermWhat it means here
CalibrationComparing an instrument's readings with a reference standard of known accuracy, traceable to national or international standards, and recording the results.
As found / as leftThe instrument's condition before any adjustment, and after calibration and adjustment.
Out of tolerance (OOT)An as-found result outside the accuracy limits set for the instrument.
Last known goodThe last date the instrument was shown to be within its limits.
Impact assessmentThe record of what an out-of-tolerance instrument measured since last known good, how the error could have affected each result, and what was decided.
Interim checkA quick check between calibrations, such as a reading on a gauge block or master.
Recall systemThe way instruments are called in before they fall due and kept from use when they do.
Measurement traceabilityAn unbroken chain of calibrations linking results to national or international standards.
Measurement uncertaintyThe doubt in a measurement result, stated as a range around the reading.
Accuracy ratioThe tolerance checked divided by the instrument's uncertainty (often aimed at 4 to 1 or better).
Guard bandA narrower acceptance limit used where measurement uncertainty is significant near a limit.
Measurement system analysis (MSA)Studies showing whether a measurement system is fit for the measurement it makes.
Gauge R&RA study of repeatability and reproducibility: how much measurement variation comes from the gauge and from the people using it.
Attribute agreementA study of whether inspectors making pass/fail decisions agree with each other and a reference.
Key characteristicA feature whose variation significantly affects fit, function, performance or service life (see AS9103).
Accredited laboratoryA calibration laboratory assessed by an accreditation body against ISO/IEC 17025 for a stated scope.

Need more than one resource, or not sure where to start? Book a complimentary 30-minute Aegis Quality Guidance Call. We'll find the tools that fit your situation and a sensible place to start. No sales pressure, no obligation.

Intervals, checks, ratios and study guidelines here are starting points. Your customers may specify their own calibration, notification and measurement system requirements (for example AS13003), and those come first.

A management aid, not certification or a registrar audit. Using it does not by itself show conformity to AS9100D or any other standard, and your customers' requirements may add to it.

Clause numbers refer to AS9100D (SAE AS9100 Rev D) unless another document is named. The standards' text is not reproduced here: use your own licensed copy.