When software decides acceptance, the software is part of the measurement system. A CMM program that measures the wrong feature, or a vision recipe with the wrong tolerance, accepts bad parts as reliably as a worn gauge. Treat them the same way:
- Each program or recipe that accepts product has an ID and a revision, on the register or a linked list.
- A new or changed program is verified before use: run it on a known part or artifact and compare with independent results. Record who verified it and when.
- Changes are controlled: who may edit, how the change is recorded, and which revision is released to the machine.
- Software updates to the measuring system itself (CMM software, test software) are followed by a verification run on the reference artifact.
- Test equipment (pressure, electrical, leak) follows the same register, recall and assessment path as dimensional gauges.
Need more than one resource, or not sure where to start? Book a complimentary 30-minute Aegis Quality Guidance Call. We'll find the tools that fit your situation and a sensible place to start. No sales pressure, no obligation.
A management aid, not certification or a registrar audit. Using it does not by itself show conformity to AS9100D or any other standard, and your customers' requirements may add to it.
Clause numbers refer to AS9100D (SAE AS9100 Rev D) unless another document is named. The standards' text is not reproduced here: use your own licensed copy.